Electrode HA series
Choose Models for offer request
Intended
- Equithal/Argenthal system
- Accurate measurement
- Ceramic diaphragms
- Long service life
- Pressure up to 6 bar
- Possibility of sterilization
- Ceramic membrane
Characteristic
Available Models
The HA465-50 electrode is an electrolyte-filled chemical electrode with a patented silver ion trap. Ensures accurate results in chemical applications for a long time. The HA465-50 electrode is equipped with 3 more porous ceramic diaphragms. The electrode is filled with a liquid Viscolyt electrolyte to ensure optimal performance in the often harsh conditions found in chemical applications. The product is equipped with a patented silver ion trap that prevents the formation of silver sulfide deposits on the diaphragm when the electrode is in contact with a medium containing sulfides. This solution significantly extends the life of the electrode. This model is especially dedicated to installation in tanks with a pressure of up to 6 bar.
The HA465-50-EQ electrode provides a very fast response to temperature changes. The HA465-50-EQ is equipped with a special Equithal reference system, which gives it a significantly faster response (up to 10 times) to rapid changes in process temperature. The Friscolyte-B reference liquid electrolyte is suitable for measurements in media containing proteins and organic solvents. The electrode can be operated for a long time, because it is possible to refill it with electrolyte, which also contributes to low operating costs. This model is especially dedicated to installation in tanks with pressure up to 6 bar.
Low maintenance gel probe HA405-DPA for use in chemical and water applications. It is filled with a gel electrolyte and is intended for use in in-line measurements in chemical and water applications. The electrode is dedicated to use in reactors, tanks, pools and transmission lines - wherever there are particularly difficult process conditions resulting from the chemical composition of the tested medium. The HA405-DPA probe is filled with a gel reference electrolyte that is pressurized to 2.5 bar, which provides a gradual flow of electrolyte that effectively cleans the diaphragm while preventing process media from entering the electrode.
The HA405-DXK-S8 pH electrode uses the XEROLYT® reference system, designed for high pressure chemical applications. It is a low maintenance pH electrode. Resistant to high pressure and can be used in harsh chemical applications. The polymer electrolyte remains in direct contact with the process medium (there is no refilling of the electrolyte and keeping it under pressure). Due to the presence of an open junction, there is no problem of clogging in contaminated media with this electrode.
Technical specification:
Technical specification | HA465-50-EQ-T-S7/9848 | HA465-50-SC-T-S7 | HA405-DPA-SC-S8 | HA405-DXK-S8 |
number of membranes | 3 | 3 | 1 | 1 |
silver ion trap | no | yes | yes | no |
membrane | ceramic | ceramic | ceramic | open apparatus connection |
temperature | / | 0-130°C | 0-100°C | 0-110°C |
pH range | 0-12 | 0-14 | 0-14 | 2-14 |
pressure resistance (bar) | Overpressure up to 6 bar | Overpressure up to 6 bar | Overpressure up to 2.5 bar | 16 bar / 25°C 6 bar/ 100°C |
pressure resistance (psi) | Overpressure up to 87 psi | Overpressure up to 87 psi | Overpressure up to 36 psi | 232 psi / 77°F 87 psi / 212°F |
reference system | Equithal | Argenthal | Argenthal | Argenthal |
autoclavable | no | no | no | no |
ISM | no | no | no | no |
technical data | pH electrode filling with liquid electrolyte | pH electrode filling with liquid electrolyte | pH electrode with low maintenance requirements | Low maintenance pH electrode with polymer electrolyte |
Model | Parameter | Temperature [° C] | Options |
---|---|---|---|
HA465-50-SC-T-S7 | 0-14 pH | 0-130 °C | 3 membranes |
HA465-50-EQ-T-S7/9848 | 0-12 pH | - | 3 membranes |
HA405-DPA-SC-S8 | 0-14 pH | 0-100 °C | 1 membrane |
HA405-DXK-S8 | 2-14 pH | 0-110 °C | 1 membrane |
Check also