EN PL

MD 110 photometer

Choose Models for offer request

Intended

  • Bluetooth® interface
  • Automatic shutdown
  • Calibration mode indicator
  • Backlit display
  • Easy to use
Bluetooth-enabled photometer

All MD 110 photometers include Bluetooth® functionality. To make the best use of this, Tintometer offers an app for mobile devices, as well as computer software with a dongle. Measurement results are sent to external devices via Bluetooth® for quick evaluation and processing, so all data can be analyzed and attributed directly on site.

 
Features:

  • Waterproof design

The design of the device ensures that the meter is waterproof for up to 1 hour at a depth of about 0.1 meters. The meter floats on water.

 

  • User calibration mode

Single-point calibration is possible. In addition, all MD 110 instruments have the ability to display readings directly in ABS or %T units.

 

  • One-time reset function

When testing a new sample, zero the instrument once, and all subsequent tests of that sample do not require resetting the instrument.

 

  • Ergonomic design

Whether using the MD110 in the field or in the lab, the meter's design makes it easy to operate and view the display.

 

  • Factory programmed

All MD 110 instruments come ready to use with up to 14 calibration curves. All you have to do is select the test you need, prepare the sample and test!




Number of parameters Description Parameter and range Catalog number

Single

MD 110 ChZT

ChZT HR TT 200 - 15000 mg/l CODb)

ChZT LMR TT 15 - 300 mg/l CODb)

ChZT LR TT 3 - 150 mg/l CODb)

ChZT MR TT 20 - 1500 mg/l CODb)

2961202

3 in 1

MD 110 Chlorine, pH, cyanuric acid, reagents in tablets

Chlorine HR T 0.1 - 10 mg/l Cl2 a)

Chlorine L 0.02 - 4.0 mg/l Cl2 a)

Chlorine T 0.01 - 6.0 mg/l Cl2 a)

CyA T 10 - 160 mg/l CyA

pH L 6.5 - 8.4

pH T 6.5 - 8.4

2980102

3 in 1

MD 110 Chlorine, pH, cyanuric acid, liquid reagents

Chlorine HR T 0.1 - 10 mg/l Cl2 a)

Chlorine L 0.02 - 4.0 mg/l Cl2 a)

Chlorine T 0.01 - 6.0 mg/l Cl2 a)

CyA T 10 - 160 mg/l CyA

pH L 6.5 - 8.4

pH T 6.5 - 8.4

2980152

4 in 1

MD 110 Chlorine, pH, cyanuric acid, alkalinity-m, tablet reagents

Alkalinity T 5 - 200 mg/l CaCO3

Chlorine HR T 0.1 - 10 mg/l Cl2 a)

Chlorine L 0.02 - 4.0 mg/l Cl2 a)

Chlorine T 0.01 - 6.0 mg/l Cl2 a)

CyA T 10 - 160 mg/l CyA

pH L 6.5 - 8.4

pH T 6.5 - 8.4

2980702

4 in 1

MD 110 Chlorine, pH, cyanuric acid, alkalinity-m, liquid reagents

Alkalinity T 5 - 200 mg/l CaCO3

Chlorine HR T 0.1 - 10 mg/l Cl2 a)

Chlorine L 0.02 - 4.0 mg/l Cl2 a)

Chlorine T 0.01 - 6.0 mg/l Cl2 a)

CyA T 10 - 160 mg/l CyA

pH L 6.5 - 8.4

pH T 6.5 - 8.4

2980752

6 in 1

MD 110 Chlorine, bromine, pH, cyanuric acid, alkalinity-m, calcium hardness, tablet reagents

Alkalinity T 5 - 200 mg/l CaCO3

Bromine T 0.05 - 13 mg/l Br2

Chlorine HR T 0.1 - 10 mg/l Cl2 a)

Chlorine L 0.02 - 4.0 mg/l Cl2 a)

Chlorine T 0.01 - 6.0 mg/l Cl2 a)

CyA T 10 - 160 mg/l CyA

Hardness (B) T 20 - 500 mg/l CaCO3

pH L 6.5 - 8.4

pH T 6.5 - 8.4

2980902

Boiler water

MD 110 Boiler water

Aluminum PP 0.01 - 0.25 mg/l Al

Chloride L (A) 0.5 - 20 mg/l Cl-

Copper T 0.05 - 5 mg/l Cua)

DEHA PP 0.02 - 0.5 mg/l DEHA

Hydrazine P 0.05 - 0.5 mg/l N2H4

Iron LR L (A) 0.03 - 2 mg/l Fe

Dissolved oxygen C 10 - 800 µg/l O2 (c)

Phosphate HR L 5 - 80 mg/l PO4

Polyacrylate L 1 - 30 mg/l Polyacrylate

Silica HR PP 1 - 90 mg/l SiO2

2962302

Cooling water

MD 110 Cooling water

16 parameters

2962402



Link to the manufacturer's website:

https://www.lovibond.com/en/PW/Water-Testing/Products/Lab-Portable-Instruments/ColorimetersPhotometers/MD-110-Photometer