Semi-automatic M3000 meter
Choose Models for offer request
Intended
- Semi-automatic measurement
- 3 capillary inlets
- LCD display
- Monitoring of the illuminated sample through the lens
- Fast cooling thanks to integrated fan
- Digital display of all important data
- Display in German or English
- With RS-232 interface for CBM910 printer
- Easy-to-clean membrane keypad
- Includes protective cover and 100 capillaries
- Small sample volume
Characteristic
Available Models
Semi-automatic measurement using 10x observation optics
The M3000 provides fast and easy testing of bulk substances with melting points up to 360 °C. Thanks to the triple capillary approach, it is possible to analyze three samples in one measurement run. Thanks to the preheating speed and integrated fan cooling, fast measurements in any temperature range are possible. The display provides a clear readout of all important measurement data.
- Typical applications
Determining the melting point is of great importance in substance identification studies, as many substances can be determined by their melting points. The purity of a substance can also be measured qualitatively from its melting point. A well-defined melting point is only given for substances that are 100% pure. Due to impurities, such as impurities or admixtures, most substances have a melting range (from the beginning to the end of the melting process) of a few degrees Celsius. Even impurities during the production of chemicals extend this melting point to a certain melting range. As a result, most substances that are tested with a melting point meter have a melting interval. This effect is intended to determine the degree of contamination of a substance.
- Advantages of automatic and semi-automatic measurement
- Certified traceable calibration standards for melting point determination
To meet the requirements for verifiability and traceability of results, we have ready-made standards and reference materials. The use of these standards ensures reliable analytical results and reduces the laboratory's validation effort.
Technical specification:
Model | M3000 |
Measurement range (°C) | 30-360°C |
Measurement accuracy (°C) | ±0,3 °C (30–200 °C) ±0,5 °C (200–360 °C) |
Repeatability (°C) | 0,1°C |
Heating rate | To 200 °C approx. 4,0 min To 300°C approx. 8,0 min |
Heating rate (min-1) | 1°C min-1 |
Number of capillary inlets | 3 |
Capillary | 1,4 mm |
Interfaces | RS-232 |
Protection class | IP20 |
Power supply | 90–264 V |
Dimensions (szer. x wys. x głęb.) mm | 210 x 360 x 230 |
Weight (kg) | 4,3 kg |
Melting point standards:
Number | Standards |
KSPS1011 | Standard melting point of vanillin (USP reference standard) - 81 - 83 °C |
KSPS1012 | Phenacetin melting point standard (USP reference standard) - 133 - 136 °C |
KSPS1013 | Sulfonilamide melting point standard (USP reference standard) - 164 - 166 °C |
KSPS1014 | Caffeine melting point standard (USP reference standard) - 234 - 236.5°C |
KSPS1015 | Vanillin melting point standard (secondary pharmaceutical standard) - 81 - 83 °C |
KSPS1016 | Phenacetin melting point standard (secondary pharmaceutical standard) - 133 - 136 °C |
KSPS1017 | Melting point standard for sulfonilamide (secondary pharmaceutical standard) - 164 - 166 °C |
KSPS1018 | Caffeine melting point standard (Pharmaceutical Secondary Standard) - 234 - 236.5°C |
Model | Accuracy |
---|---|
M3000 | ±0,3 °C (30–200 °C) ±0,5 °C (200–360 °C) |