Semi-automatic M3000 meter

Choose Models for offer request

Intended

  • iso-9001-copy
  • shape-2601
  • shape-2680
  • iso-9001-copy
  • shape-2601
  • shape-2680
  • Semi-automatic measurement
  • 3 capillary inlets
  • LCD display
  • Monitoring of the illuminated sample through the lens
  • Fast cooling thanks to integrated fan
  • Digital display of all important data
  • Display in German or English
  • With RS-232 interface for CBM910 printer
  • Easy-to-clean membrane keypad
  • Includes protective cover and 100 capillaries
  • Small sample volume

Semi-automatic measurement using 10x observation optics

The M3000 provides fast and easy testing of bulk substances with melting points up to 360 °C. Thanks to the triple capillary approach, it is possible to analyze three samples in one measurement run. Thanks to the preheating speed and integrated fan cooling, fast measurements in any temperature range are possible. The display provides a clear readout of all important measurement data.

  • Typical applications

Determining the melting point is of great importance in substance identification studies, as many substances can be determined by their melting points. The purity of a substance can also be measured qualitatively from its melting point. A well-defined melting point is only given for substances that are 100% pure. Due to impurities, such as impurities or admixtures, most substances have a melting range (from the beginning to the end of the melting process) of a few degrees Celsius. Even impurities during the production of chemicals extend this melting point to a certain melting range. As a result, most substances that are tested with a melting point meter have a melting interval. This effect is intended to determine the degree of contamination of a substance.

  • Advantages of automatic and semi-automatic measurement
Melting point determination is a basic technique for analyzing samples, providing important information about the composition and purity of the material. It is also a technique that can be performed without specialized equipment.

  • Certified traceable calibration standards for melting point determination

To meet the requirements for verifiability and traceability of results, we have ready-made standards and reference materials. The use of these standards ensures reliable analytical results and reduces the laboratory's validation effort.


Technical specification:

Model M3000
 Measurement range (°C) 30-360°C
Measurement accuracy (°C) ±0,3 °C (30–200 °C)
±0,5 °C (200–360 °C)
Repeatability (°C) 0,1°C
Heating rate To 200 °C approx. 4,0 min
To 300°C approx. 8,0 min
Heating rate  (min-1) 1°C min-1
Number of capillary inlets 3
Capillary 1,4 mm
Interfaces RS-232
Protection class IP20
Power supply 90–264 V
Dimensions (szer. x wys. x głęb.) mm 210 x 360 x 230
Weight (kg) 4,3 kg

Melting point standards:

Number Standards
KSPS1011 Standard melting point of vanillin (USP reference standard) - 81 - 83 °C
KSPS1012 Phenacetin melting point standard (USP reference standard) - 133 - 136 °C
KSPS1013 Sulfonilamide melting point standard (USP reference standard) - 164 - 166 °C
KSPS1014 Caffeine melting point standard (USP reference standard) - 234 - 236.5°C
KSPS1015 Vanillin melting point standard (secondary pharmaceutical standard) - 81 - 83 °C
KSPS1016 Phenacetin melting point standard (secondary pharmaceutical standard) - 133 - 136 °C
KSPS1017 Melting point standard for sulfonilamide (secondary pharmaceutical standard) - 164 - 166 °C
KSPS1018 Caffeine melting point standard (Pharmaceutical Secondary Standard) - 234 - 236.5°C
Model Accuracy
M3000 ±0,3 °C (30–200 °C) ±0,5 °C (200–360 °C)