Standard incubators with natural nonvection
-
Series BD Classic.Line Binder incubator
Producer: Binder
Nr CAT:
Capacity: 20 L, 400 L
Scale: 27 kg, 135 kg
check -
Series BD Avantgarde.Line Binder incubator
Producer: Binder
Nr CAT:
Capacity: 57 L, 112 L, 253 L, 737 L
Scale: 39 kg, 54 kg, 85 kg, 169 kg
check -
Series CG Wamed incubators
Producer: Wamed
Nr CAT:
Capacity: 17 L, 39 L, 75 L, 115 L, 144 L, 150 L, 220 L
Scale: 24 kg, 35 kg, 45 kg, 57 kg, 79 kg, 89 kg
check -
Series TIN-IN Phoenix Incubator
Producer:
Nr CAT:
Capacity: 16 L, 35 L, 55 L, 120 L, 200 L
Temperature range [° C]: +5 to +70
check
Laboratory incubators with natural air circulation allow samples to be heated with the free flow of air in the heat chamber. With the use of natural air circulation inside the chamber, there is no concern that the samples inside the chamber will move or there will be a transfer of pathogens from one incubated dish to another, as the air circulation inside is extremely gentle. Natural air circulation warmers can be equipped with analog control, or more sophisticated models can have microprocessor control. The tested, incubated material is subjected to a stable, homogeneous temperature rise, which protects against stress on the samples and the formation of local overheating of the material. Natural convection warmers typically operate in temperature ranges from +30 °C to 70 °C, and some models can reach temperatures of up to 100 °C. Natural convection warmers enable reliable incubation of microbial cultures and guarantee results that can be replicated in any routine process in the laboratory, even in situations with a large number of samples in a single batch or when the device is operated for long periods of time. The capacities of natural air circulation warmers available in our company's offer are very different - starting from a dozen liters and ending even with devices having several hundred liters. It should be borne in mind that the larger the capacity of the chamber of a natural air circulation thermometer, the longer the time required to equalize the temperature inside after starting the device or opening the door to inspect the contents of the interior. Some of the models have a single door, while they may be partially glazed, may have a "window"-through which, even despite the single door, you can inspect the interior. Other available models may have a double door as standard or optional, the inner door is glass, and the outer door is solid. In the case of double doors, when the lab technician wants to see the contents inside, he opens only the outer door, and the inner door prevents disruption of convection inside and temperature drop.More advanced natural convection heaters have the ability to communicate via a USB port, or RS232 port, as well as have the ability to remotely control or connect to the LIMS network of the laboratory. Advanced devices are equipped with a number of acoustic and visual alarms, as well as the ability to record the processes going on inside, so that the work with a given hothouse is in accordance with GMP and guarantees maximum safety of the material inside the chamber. Wide possibilities of programming the devices, the ability to set a delayed start allows maximum flexibility in the use of the devices for the purposes of a particular laboratory. The accuracy of temperature stabilization of the most advanced devices can be up to +/- 0.1 ° C. Natural circulation warmers have double independent protection systems against uncontrolled temperature rise. We invite you to make inquiries at our company, where qualified customer advisors will help you select the most optimal device for your purposes. Our company provides services to check the temperature distribution inside the device, which is particularly important during clinical trials and other processes where documenting temperature stability is important. Our qualified service technicians train, install and service the device.